Adjust the dBA-level trimmer (1) to its maximum by turning it fully clockwise.
Adjust the volume on the amplifier to minimum.
Slide NORMAL / PINK NOISE switch (4) to the PINK NOISE-position (lowest position).
Use a sound level meter set to “dBA” and “slow or average response” to measure the sound
pressure level at an appropriate position in the room.
Adjust the volume on the amplifier to about 10 dBA above the desired or allowed sound level.
Adjust the dBA-level trimmer (1) slowly until the sound level meter indicates the maximum
allowed sound level. The yellow LED’s in the middle of the sound level LED-bar (6) should
illuminate and the gain reduction LED-bar should give an indication that the ARGOS is
reducing the gain.
Slide the NORMAL / PINK NOISE switch (4) back to NORMAL (upper position).
Mount the frontpanel coverplate and seal it. The ARGOS is ready for use.
LINE (LINE-BASED OPERATION) :
When to use ?
When more then 1 amplifier is used and if the maximum admissible sound level is < 80dBA
In these cases where the use of a microphone is not desired.
When the ARGOS is used in mobile installations to protect the speakers from overload.
When the ARGOS is used as a sound leveler.
How to calibrate ?
Connect the LINE outputs of the preamplifier or mixing desk or to the corresponding LINE-
inputs at the rearpanel of the ARGOS.
The microphone should not be connected.
Slide the mode selection switch (2) to the upper position so the LINE-indicator (10) is lit.
Slide the FAST / SLOW-switch (3) to the desired position. This switch should be set to FAST if
the level shouldn't even exceed the threshold for a short time. However, the SLOW mode
is much more pleasant to listen to because of the smooth operation.
Adjust the “dBA-level” trimmer (1) to its minimum by turning it fully counterclockwise.
Adjust the volume of the amplifier(s) to minimum.
Slide the NORMAL / PINK NOISE-switch (4) to the PINK NOISE position
Adjust the volume of the amplifier(s) to maximum.
Use a sound level meter set to “dBA” and “slow or average response” to measure the sound
pressure level at an appropriate position in the room.
Adjust the dBA-level trimmer (1) slowly until the sound level meter indicates the maximum
allowed sound level. The yellow LED’s in the middle of the sound level LED-bar (6) should
illuminate and the gain reduction LED-bar should give an indication that the ARGOS is
reducing the gain.
Slide the NORMAL / PINK NOISE switch (4) back to NORMAL (upper position).
Mount the frontpanel coverplate and seal it. The ARGOS is ready for use.